MAINTENANCE AND STORAGE
If the water is hard, meaning that it contains too much calcium and magnesium, it may leave a white powder in the
appliance and cause scum to form at the surface of the tank, on the transducer (metal disc producing the ultrasonic
waves), and on the inside walls of the water tank. Scum on the surface of the transducer will prevent the appliance from
operating properly.
We recommend
• Using clean, fresh, boiled and cooled water or distilled or demineralised water each time the appliance is used,
• Cleaning the tank every three days, cleaning the transducer every week,
• Changing the water in the tank often so that it stays fresh – don't leave it for more than two days,
• Cleaning the whole appliance and ascertaining that all the components are perfectly dry when it is not in use.
To clean the transducer
Put 2 to 5 drops of vinegar on the surface and leave it from 2 to 5 minutes.
Brush the scum from the surface with a soft brush. Do not use a hard tool or scratch the surface.
Rinse the transducer with clean water.
Do not use soap or other alkaline substances to clean the transducer.
To clean the tank
Clean the water tank with a soft cloth and vinegar if there is foam OR a calcium deposit in it.
If foam covers the safety switch, put a few drops of vinegar on it and clean it with the brush.
Rinse the tank with clean water.
Storage
Clean and dry the ultrasonic humidifier carefully, complying with the maintenance instructions.
Let it dry completely before storing it. Do not store with water in the base.
Store the appliance in a dry cool place, out of the reach of children.
PROBLEMS AND SOLUTIONS
In the event of malfunctioning under normal conditions of use, please refer to the following table:
PROBLEM POSSIBLE CAUSES SOLUTIONS
Fan not working, no mist
No electric current Plug in the appliance
Main switch closed Turn on main switch
The water level in the tank is too low Add water to the tank
The water level in the tank is too low Add water to the tank
Fan working, but no mist
No water in the tank Fill the tank
The water level indicator is not in the
right position
Correctly reposition the water level
indicator
The temperature of the unit is too low Put the unit in a room at ambient
temperature for half an hour before
use.